Space Charge Measurement System
Space Charge Measurement System for flat samples
Measurement system:
- PEA (pulsed electroacoustic method) space charge measurement system.
Test specimen dimensions:
- Flat test specimen plates with a thickness of up to 0.5 mm
Voltage load:
- Voltages up to 30 kV DC
Measured values:
- Space charge distribution over the thickness of the test specimen
- Changes in space charge distribution over time
- Change in space charge distribution over time and over the given load profile
Raumladungsmesssystem für Modellkabel
Measurement system:
- PEA (pulsed electroacoustic method) space charge measurement system.
Test specimen dimensions:
- Coaxial cable (model cable or medium voltage cable)
- Insulation thickness: 3 mm - 15 mm
- Outer diameter: 20 mm - 130 mm
Voltage load:
- Voltages up to 100 kV DC
Measured values:
- Space charge distribution in radial direction of the cable insulation
- Changes in space charge distribution over time
- Change in space charge distribution over time and over the given load profile